AWI INDUSTRIES
Home  |  News  |  About AWI  |  Contact us
WELCOME TO A.W.I. INDUSTRIES (USA) INC.
top menu

Home

Optics

Laser

Plastics

Electronics
NightStar
 

NightStar Accessories

Magnetic Force Flashlight

Specification

bottom menu

 

 

NightStar Specification

IMAGE

Click on image for enlarged picture

LIGHT OUTPUT

Click on image for enlarged picture Click on image for enlarged picture

[ Tests Performed by Hauser Laboratories ]  

HAZARDOUS CLASS 1 GAS CERTIFICATIONS

Meets all test criteria for MIL-STD-810F, Test Method 511.4: Military Standard Reliability Program. Gas Mixtures tested: Acetylene (Group A), Hydrogen (Group B), Ethylene (Group C), Hexane (Group D), Natural Gas (Group D), Aviation AV/ Gas 100 / 130.

[ Tests Performed by Aero Nav Laboratories ]

ELECTROMAGNETIC COMPATIBILITY

Conforms to Council Directive 89/336/EC. Measured RF levels are far below limits for all frequencies.

[ Tests Performed by Labein Laboratories ]  

TEMPERATURE

Storage: -50°F (-45°C) to 140°F (60°C)
Operation: -40°F (-40°C) to 130°F (55°C).

[ Tests Performed by Hauser Laboratories ]  

CORROSION RESISTANCE

Operational after 3 days immersion in solutions of salt water, isopropyl alcohol, ammonia, phosphoric acid*, acetic acid*, drain cleaner*, Ajax*, motor oil and diesel fuel (* 10% solutions).

[ Tests Performed by Hauser Laboratories ]  

SUBMERSION

Operational at an ocean depth of 2210-ft (674m)

[ Equivalent pressure crush point:960 PSI ]  

[ Tests Performed by Hauser Laboratories ]  

SOUND EMISSION

Overall A-Weighted Sound Power Level: 63.6 dB

No# of units

Distance (ft)
  1 10 100 1000 10000
1 65 45 25 5 0
12 (squad) 76 56 36 16 0
36 (platoon) 81 61 41 21 1
108 (company) 86 66 46 26 6

All values are A-Weighted Sound Pressure Levels and are predictions based on measured Overall A-Weighted Sound Power Levels of a single unit. For reference purposes, a pressure level of 40 is equivalent to an urban neighborhood at night far from roads. A pressure level of 20 is an empty recording studio.  

MAGNETIC FIELD STRENGTH

Single Unit @ 1ft. @ 2ft. @ 4ft. @ 8ft
Axis 1 0.03 0.005 0.0005 0.00001
Axis 2 0.06 0.007 0.0005 0.00001
Axis 3 0.13 0.028 0.0040 0.00050
1 Case (packed in alternating configuration):
Axis 1 0.22 0.002 0.0001 0.00001
Axis 2 0.006 0.001 0.00000 0.00000
Axis 3 0.06 0.006 0.001 0.00001

Note: All values are in Guass. Axis 1 is parallel to the housing, Axis 2 is perpendicular to the housing, Axis 3 is perpendicular to the end of the light. For reference purposes, a field of 0.005 G deflects a compass needle by less than 1 degree.

[ Tests performed by Washington Laboratories ]  

WEIGHT / MASS / LENGTH

11 ounces / 308 grams / 10" (25.4cm).  

Copyright © 1999-2003 - A.W.I. INDUSTRIES (USA) INC.
All rights reserved

Version 3.4, July 2003 - Designed by JVT